System Description
XP | XPT |
|
|
Applications
- Targeted corrosion prevention for patch repairs and joints
Product Details
Corrosion Prevention Spacing: 7″ – 30″ (175 – 750 mm)
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Bar shaped discrete anode
- Extra long tie wires
- Alkali-activated zinc
- 2G Technology
Applications
- Corrosion prevention in new construction
- Global protection
- Targeted protection around construction joints and other problematic areas
Product Details
Corrosion Prevention Spacing: 1 anode per 2.7 ft2 (0.25m2) of steel surface area, maximum 30” (750mm) between anodes
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Oval shaped discrete anode
- Extra long tie wires
- Alkali-activated zinc
- 2G Technology
- BarFit groove for secure anode placement
Applications
- Targeted corrosion prevention for patch repairs and joints
Product Details
- Corrosion Prevention Spacing: 12″ – 30″ (300 – 750 mm)
- Corrosion Control Spacing: 8″ – 24″ (200 – 600 mm)
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Oval shaped discrete anode
- Alkali-activated zinc
- 2G Technology
- BatFit groove for secure anode placement
Applications
- Targeted corrosion prevention or corrosion control for patch repairs and joints
- High chloride or high steel density applications
Product Details
Corrosion Control Spacing: 6″ – 30″ (150 – 750 mm)
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Cyclindrical shaped discrete anode
- Alkali-activated zinc
- 2G Technology
Applications
- Corrosion control for concrete
Product Details
Corrosion Control Spacing: 13″ – 28″ (325 – 700 mm)
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Bar shaped discrete anodes
- Halide-activated zinc
- Barfit plastic spacers
Applications
- Targeted corrosion prevention for patch repairs and joints
Product Details
Corrosion Prevention Spacing: 7″ – 30″ (175 – 750 mm)
Vector Services
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Embedded anodes for distributed protection
- Alkali-activated zinc
Applications
- Galvanic encasement’s
- Jacketing
- overlays
Product Details
Anode selection and spacing based on design requirements
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Heavy distributed galvanic anodes for marine structures
- Alkali-activated zinc
- Mortar covered
Applications
- Galvanic encasement’s, jacketing and overlays
- Tidal zone and dry, non-wetted concrete in marine environment
Product Details
Anode selection and spacing based on design requirements
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Galvanic anodes with a stay-in-place formwork
- Distributed alkali-activated anodes or zinc mesh anodes
- Bulk zinc anodes
Applications
- Galvanic encasement’s , jacketing and overlays
- For marine and non-marine environments
Product Details
Anode selection and spacing based on design requirements
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Metallized zinc anode for concrete
- Humectant activator
Applications
- Large area protection such as bridges and marine structures
Product Details
- Anode thickness: 10 – 20 mils (250 – 500 μm)
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Surface mounted zinc anode for concrete
- Ionically conductive adhesive
Applications
- Global protection or targeted corrosion control
Product Details
- Anode thickness: 10 mils (250 µm)
- Anode coverage typically 50 – 100% of concrete surface
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Cylindrical or star shaped discrete anodes with high current capacity
- Built in ventilation
- Crimps or electrical connectors
- Ebofix® Grout
Applications
- Global protection or targeted protection
- Reinforced concrete or masonry structures
Product Details
- Anode sizes: 7 – 28 mm diameter, lengths up to 600 mm
- Anode spacing based on design requirements
Vector Services
System Design – Materials Supply – On-site Technical Service – System Installation
System Description
- Surface adhered MMO Titanium Tape anode for distributed protection
Applications
- Global or targeted protection for reinforced concrete
Product Details
- Anodes width: 0.4″ – 2″ (10 – 50 mm)
- Anode spacing based on design requirements
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Range of MMO Titanium anodes and related components
Applications
- Global or targeted protection – Reinforced concrete, masonry, or buried structures
Product Details
- Mesh, Ribbon Mesh, Tubes, Wire
Vector Services
- System Design
- Materials Supply
- On-site Technical Service
- System Installation
System Description
- Long term corrosion passivation with short term electrical treatment
- Reduces chloride and increases pH around reinforcing steel
Applications
- Chloride contaminated concrete
- Large area treatment
Product Details
- 4 – 8 week treatment time
- Barrier protection recommended if re-exposed to chloride
Vector Services
- System Design
- System Installation
System Description
- Long term corrosion passivation with short term electrical treatment
- Potassium or sodium carbonate used as electrolyte
Applications
- Carbonated concrete
- Large area treatment
Product Details
- 2 – 4 week treatment time
- Will not re-carbonate
Vector Services
- System Design
- System Installation
System Description
- Drives in lithium with short term electrical treatment
- Passivates active corrosion
Applications
- Structures suffering from reactive aggregate damage and corrosion
- Large area treatment
Product Details
- 4 – 8 week treatment time
- Lithium impregnated in concrete cover
Vector Services
- System Design
- System Installation
System Description
- Locate cables and tendons
- Locate voids in cables and tendons
Applications
- Unbonded and bonded post-tension systems
Product Details
- Ground penetrating radar
- Ultrasonic shear wave tomography
Vector Services
- Field Evaluation
System Description
- Determines probability of corrosion inside post-tension ducts
Applications
- Unbonded post-tension systems
- Parking Garages and Buildings
Product Details
- Low volume of dry gas passed through ducts
- Representative sampling
Vector Services
- System Design
- System Installation
System Description
- Detects broken post-tension cables and tendons
Applications
- Unbonded and bonded post-tension systems
- Bridges and Parking Garages
Product Details
- Uses remanent magnetism (RM) method
Vector Services
- System Design
- System Installation
System Description
- Mitigates corrosion by removing moisture from cable system
Applications
- Unbonded post-tension systems
- Parking garages and buildings
Product Details
- Large area treatment
- System continues in operation until moisture is at negligible level
Vector Services
- System Design
- System Installation
System Description
- Protects steel in post-tension ducts with innovative, low viscosity impregnation material
Applications
- Bonded post-tension systems
Product Details
- Material selection and techniques selected based on repair requirements
Vector Services
- System Design
- System Installation