1. Galvanic Systems

System Description

XP XPT
  • disc shaped discrete anode
  • Alkali-activated zinc
  • 2G Technology
  • bar shaped discrete anode
  • Alkali-activated zinc
  • 2G Technology

Applications

  • Targeted corrosion prevention for patch repairs and joints

Product Details

Corrosion Prevention Spacing: 7″ – 30″ (175 – 750 mm)

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation
     

System Description

  • Bar shaped discrete anode
  • Extra long tie wires
  • Alkali-activated zinc
  • 2G Technology

Applications

  • Corrosion prevention in new construction
  • Global protection 
  • Targeted protection around construction joints and other problematic areas

Product Details

Corrosion Prevention Spacing: 1 anode per 2.7 ft2 (0.25m2) of steel surface area, maximum 30” (750mm) between anodes

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Oval shaped discrete anode
  • Extra long tie wires
  • Alkali-activated zinc
  • 2G Technology
  • BarFit groove for secure anode placement

Applications

  • Targeted corrosion prevention for patch repairs and joints

Product Details

  • Corrosion Prevention Spacing: 12″ – 30″ (300 – 750 mm)
  • Corrosion Control Spacing: 8″ – 24″ (200 – 600 mm)

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Oval shaped discrete anode
  • Alkali-activated zinc
  • 2G Technology
  • BatFit groove for secure anode placement

Applications

  • Targeted corrosion prevention or corrosion control for patch repairs and joints
  • High chloride or high steel density applications

Product Details

Corrosion Control Spacing: 6″ – 30″ (150 – 750 mm)

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Cyclindrical shaped discrete anode
  • Alkali-activated zinc
  • 2G Technology

Applications

  • Corrosion control for concrete

Product Details

Corrosion Control Spacing: 13″ – 28″ (325 – 700 mm)

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Bar shaped discrete anodes
  • Halide-activated zinc
  • Barfit plastic spacers

Applications

  • Targeted corrosion prevention for patch repairs and joints

Product Details

Corrosion Prevention Spacing: 7″ – 30″ (175 – 750 mm)

Vector Services

  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Embedded anodes for distributed protection 
  • Alkali-activated zinc

Applications

  • Galvanic encasement’s 
  • Jacketing
  • overlays

Product Details

Anode selection and spacing based on design requirements

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Heavy distributed galvanic anodes for marine structures
  • Alkali-activated zinc
  • Mortar covered

Applications

  • Galvanic encasement’s, jacketing and overlays
  • Tidal zone and dry, non-wetted concrete in marine environment

Product Details

Anode selection and spacing based on design requirements

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Galvanic anodes with a stay-in-place formwork
  • Distributed alkali-activated anodes or zinc mesh anodes
  • Bulk zinc anodes

Applications

  • Galvanic encasement’s , jacketing and overlays
  • For marine and non-marine environments

Product Details

Anode selection and spacing based on design requirements

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Metallized zinc anode for concrete
  • Humectant activator 

Applications

  • Large area protection such as bridges and marine structures

Product Details

  • Anode thickness: 10 – 20 mils (250 – 500 μm)

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Surface mounted zinc anode for concrete
  • Ionically conductive adhesive 

Applications

  • Global protection or targeted corrosion control

Product Details

  • Anode thickness: 10 mils (250 µm)
  • Anode coverage typically 50 – 100% of concrete surface

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

2. Impressed Current Systems

System Description

  • Cylindrical or star shaped discrete anodes with high current capacity
  • Built in ventilation
  • Crimps or electrical connectors
  • Ebofix® Grout

Applications

  • Global protection or targeted protection 
  • Reinforced concrete or masonry structures

Product Details

  • Anode sizes: 7 – 28 mm diameter, lengths up to 600 mm
  • Anode spacing based on design requirements

Vector Services

System Design – Materials Supply –  On-site Technical Service – System Installation

System Description

  • Surface adhered MMO Titanium Tape anode for distributed protection 

Applications

  • Global or targeted protection for reinforced concrete

Product Details

  • Anodes width: 0.4″ – 2″ (10 – 50 mm)
  • Anode spacing based on design requirements 

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

System Description

  • Range of MMO Titanium anodes and related components

Applications

  • Global or targeted protection – Reinforced concrete, masonry, or buried structures

Product Details

  • Mesh, Ribbon Mesh, Tubes, Wire

Vector Services

  • System Design
  • Materials Supply
  • On-site Technical Service
  • System Installation

3. Electro-Chemical Treatments

System Description

  • Long term corrosion passivation with short term electrical treatment
  • Reduces chloride and increases pH around reinforcing steel

Applications

  • Chloride contaminated concrete
  • Large area treatment

Product Details

  • 4 – 8 week treatment time
  • Barrier protection recommended if re-exposed to chloride

Vector Services

  • System Design
  • System Installation

System Description

  • Long term corrosion passivation with short term electrical treatment
  • Potassium or sodium carbonate used as electrolyte

Applications

  • Carbonated concrete
  • Large area treatment

Product Details

  • 2 – 4 week treatment time
  • Will not re-carbonate

Vector Services

  • System Design
  • System Installation

System Description

  • Drives in lithium with short term electrical treatment
  • Passivates active corrosion

Applications

  • Structures suffering from reactive aggregate damage and corrosion
  • Large area treatment

Product Details

  • 4 – 8 week treatment time
  • Lithium impregnated in concrete cover

Vector Services

  • System Design
  • System Installation

4. Post-Tensioned Services

System Description

  • Locate cables and tendons
  • Locate voids in cables and tendons

Applications

  • Unbonded and bonded post-tension systems

Product Details

  • Ground penetrating radar
  • Ultrasonic shear wave tomography

Vector Services

  • Field Evaluation

System Description

  • Determines probability of corrosion inside post-tension ducts

Applications

  • Unbonded post-tension systems
  • Parking Garages and Buildings

Product Details

  • Low volume of dry gas passed through ducts 
  • Representative sampling 

Vector Services

  • System Design
  • System Installation 

System Description

  • Detects broken post-tension cables and tendons

Applications

  • Unbonded and bonded post-tension systems
  • Bridges and Parking Garages

Product Details

  • Uses remanent magnetism (RM) method

Vector Services

  • System Design
  • System Installation 

System Description

  • Mitigates corrosion by removing moisture from cable system

Applications

  • Unbonded post-tension systems
  • Parking garages and buildings

Product Details

  • Large area treatment
  • System continues in operation until moisture is at negligible level

Vector Services

  • System Design
  • System Installation 

System Description

  • Protects steel in post-tension ducts with innovative, low viscosity impregnation material

Applications

  • Bonded post-tension systems

Product Details

  • Material selection and techniques selected based on repair requirements 

Vector Services

  • System Design
  • System Installation 

View and download the full VECTOR Products PDF Brochure Below. (Size: 10.2 mb)